The ONF3 demand switch ensures relaxation and vitality by protecting you against electrosmogElectrosmog is a colloquial term for all emissions from electric, magnetic, and electromagnetic fields. More from the current. Inclusive load resistor and LED control lamp.
Electric fields from the current are banished from the bed and bedroom with this demand switch. This demand switch can also be adjusted individually. As a result, it is possible to make fine adjustments for particular situations in the circuit.
Don’t worry, the activated ONF 3 demand switch does not alter the use of electrical appliances in any way. The demand switch only turns the current on the copper cable to the socket off when no power is needed and then turns it back on when power is needed.
An active demand switch switch is the foundation for the electrobiological rehabilitation of any bedroom and provides protection and relaxation for people. The modern person literally lives “under current”, but we have managed to electrify our lives. Not with natural direct current, but with the unnatural and very burdening 220 V alternating current with an average amperage of 16 A. Because the communication in the body (from the brain to the cells) is electric, this low-frequency electrosmog disrupts important functions in the human body extremely effectively. The suffering related to this is dramatic and is among the widespread diseases.
Double mains decoupling and DIRTY ELECTRICITY – this mains decoupler’s special feature – 2 turnkeys!
2 turnkeys are this product’s special features! Contrary to other demand switches, this one switches BOTH OF THE CIRCUIT’S SUPPLIES off and not just one like mains decouplers normally – thus a double shutdown. This makes it one of a kind because it actively fights against DIRTY ELECTRICITY and even outright stops it.
In our eyes, this method of switching off makes the ONF 3 one of the best DEMAND SWITCH available today if it doesn’t make the installation of permanent consumers, such as waterbeds, fridges or freezers impossible on the same circuit.
In order to easily check if the demand switch is working, you will receive an LED control light for the socket. If it says OFF, the switch has turned the power supply; there will be no more electrosmog. You and your health can only win with this combination!
Once the corresponding fuses have been found, it is easy and quick for the electrician to install the switch. Without checking the walls and the fuses, only the sockets in the bedroom will be activated, thus missing the aim. Each wall has two sides and the current goes 360 degrees and only knows one way. It is no coincidence that 95% of demand switches installed by electricians have been installed badly and do not achieve the desired result.
Controlling the mains cut-off is important!
Our experience shows us time and again that the control of the mains cut-off does not work. Very often, we experience situations in which the installed demand switch have been broken for a long time or have NEVER been turned on. Therefore, the included control light is important. The mains cut-off will have only worked if this lamp has lit up, and this happens only when no more power is needed. Control appliances with standby functions, radio alarms and lamps with power cables, and sometimes even the electric toothbrush in the bathroom.
Many appliances are permanent consumers without stand-by functions. Check your on and off switches. If they are between the transformer and the mains plug, the current is divided. However, if the switch is past the appliance’s transformer, it is not possible to switch it off. In that case, only an external socket strip with its own on- and off-switch will be able to help.
Up to 3 LED control lights per circuit with a demand switch!
» Additional LED control lights for already-installed demand switches
Demand switches, energy-saving lamps and LED – a problem with the base load!
Do not be surprised if the energy-saving lamps and LED lights do not switch on anymore if a demand switch has been installed. The reason for this is that the low amount of current that is needed to “ignite” the energy-saving lamps and LEDs. The demand switch alone will often not recognized them being switched on and the room stays dark as a result. Therefore, it is necessary for the mains decoupler to help out.
For this reason, a base load component is automatically attached to each ONF 3 demand switch to increase the base resistance. This ensures that the process of the lamp gets enough current for the demand switch to recognize it. The demand switch recognizes LEDs of at least 4 watts normally without any additional base load resistors. The Eltako GLE base load resistor is compatible with all commercial demand switch.
Power consumption is not increased by the load resistor. There are no temperature problems because the load resistor only becomes warm to the touch for a few seconds (during the switch-on process).
One load resistor is needed per power switch/breaker as long as it is not directly installed to the consumer.
Additional base load resistors for other switches or already-installed demand switches
Alternatives to the demand switch: shielded cable or shielding paint
The general problem with electric fields does not even occur with shielded cables. However, because a later installation is too expensive most of the time, this is more for house construction when the mains circuit is put in. Shielded cables are very effective, but the difference in price to regular power cables is considerable.
Another effective alternative to the demand switch is to paint and ground the wall with shielding paint. This removes existing stress caused by electric fields even more effectively and regardless of whether consumers work before or after.
Beware of metal in the bed – an important factor
The mattress and the bedding must be taken into account when thinking about electric fields. People literally bring the power to their bed if they use innerspring mattresses or mattress pads with silver threads. That is the wrong way to invest in an ONF 3 demand switch and to sleep on a mattress or duvet with silver threads, which act as antennae that attract electrosmog very effectively!!
The control light is also available separately, but you must know that only up to 3 control lights can be used per ONF 3 circuit off-switch (otherwise, the demand switch won’t switch off again). The control light is compatible with all commercial demand switches.
Sehr schneller Lieferung bei Vorkasse
Ich bin im Großen und Ganzen zufrieden mit dem Netzfreischalter; allerdings waren einige Anpassungen bei den Led Lampen notwendig, damit diese einschaten. Das ist auch schon der einzige Kritikpunkt.
Works perfectly.
Easy to install and does what it should. I can configure switch-off when needed thanks to its adjustability. I was puzzled by the resistor at first, but it made sense after switching over to LED. Very well thought out – thank you and greetings from Münster.