(N)HXMH(St)-J 5x 2,5 mm² shielded installation cable | halogen-free | plasticizer-free | electric cable for shielding alternating electrical fields LF | 41-4360

from:  137,00

Shielded electrical cable 5x 2.5 mm² to avoid electrosmog NF caused by low-frequency electrical fields. This shielded sheathed cable, also called BIO electric cable, type (N)HXMH(St)-J is halogen-free and does not contain any plasticisers.

  • Number of wires in core and cross-section: 5x 2.5 mm²
  • Length per roll: 25 metres / 100 metres
  • Price including copper surcharge

Delivery time: approx. 2-4 working days | 100 meter rolls = bulky goods

PROnatur24® SHOP
Independently verified
4.64 store rating (42 reviews) | 4.71 product rating

High-quality, shielded installation cable for the effective limitation of electrical alternating fields LF. This installation cable type (N)HXMH(St)-J is halogen-free and plasticizer-free.

5x 2,5mm²

This high-quality shielded cable enables effective shielding of low-frequency electrical fields. In contrast to the shielded PVC cable, this variant (N)HXMH(St)-J of a sheathed cable is also halogen-free (i.e. in the event of fire no corrosive / narcotic gases are produced. The smoke development remains low) and plasticiser-free. Furthermore, an improved behaviour in case of fire has been integrated. Consider that a standard electrical cable, laid during the construction of the flat or house, produces a strong electrical alternating field which reaches up to 2 meters into the room. And since the power lines in the floor, ceiling or wall are continuously under current with 16 amps and 220 volts, this LF electrosmog issue is a 24/7 topic – 24 hours and 7 days a week.

With this shielded electric cable, this problem is avoided from the outset. The low-frequency alternating fields automatically produced by the conventional household alternating current do not even leave the coated electric cable.

This (N)HXMH(St)-J shielded electric cable can be laid on and under plaster, in dry or humid rooms, on masonry, and on concrete. It is also suitable for outside use as long as it is protected from direct sunlight. It cannot be directly embedded into shaken, vibrated, or tamped concrete.

Important information about shielded home wiring:
In conjunction with shielded in-wall or flush-mounted boxes, this is the most effective way of shielding against electrosmog caused by electric fields. The commissioned electrician must be informed of the decision to use shielded cable BEFORE the tender. Laying this cable is a lot harder for the electrician, and the tender could be rejected as a result. Don’t be put off by this, just ask the next electrician. The extra effort to achieve an electrosmog-free result is always worth it.

(N)HXMH(St)-J 5x 2.5 mm² shielded electric cable, sheathed cable | Halogen free | Plasticizer-free | Laying cable to protect against electric fields LF | 41-4360

Construction of the (N)HXMH(St)-J shielded installation cable

Construction of the (N)HXMH(St)-J shielded BIO cable

1) Single-wire copper conductor
2) Insulation: joined-up polyethylene
3) Common core covering
4) (St)-Screen: foil with 1,13 mm wire
5) Outer casing: halogen-free polymer compound

Installing (N)HXMH(St)-J shielded installation cable

When installing, connect the ground wiring of the junction box to the ground wiring of the cable! Always connect yellow-green to yellow-green, do not connect them to the auxiliary wire in any case! Protect the auxiliary wire and toil with insulating tube, there can be no conductive parts in the junction box! The screen connection = lay the auxiliary wire to one side on the potential bonding bar. Do not use unshielded and shielded cables together.

Technical information on the (N)HXMH(St)-J shielded electric cable

  • Number of wires in core: 5
  • Cross-section per wire: 2,5mm²
  • Length: 25 meters / 100 meters
  • Outside diameter: approx. 13 mm
  • Cable weight: 260 g/m
  • Quantity: In rolls of 1,0 running meter. If tailor-cut for a customer, it cannot be revoked or cancelled. Request a free test sample before ordering.
  • No PVC with halogen-free polymer compound (according to DIN VDE 0250 Section 214)
  • No plasticizers for ecological constructions
  • Fire retardant according to EN 50266-2-4, EN 60332-1, IEC 60332-3 Cat. C
  • Nominal voltage U0/U: 300/500 V, current load according to VDE 0100
  • Construction according to DIN VDE 0250 Section 204/209, marking according to DIN VDE 0293
  • Test procedures according to DIN VDE 0472, test AC voltage 50 Hz, 3500 V
  • Bending radius according to DIN VDE 0298: 4 x D
  • Operating temperature: -30°C bis +70°C, cabling temperature -5°C bis +70°C
  • Application: Reduce LF fields
  • Field type: LF (low-frequency alternating fields)

The temperature range (not moved) is – 40º C to max. + 70º C, during installation + 5º C to max. + 70º C. Outdoor installation is only possible if the cable is not exposed to direct sunlight. Use in hazardous areas is not permitted. The product conforms to the 73/23/EEC Directive (Low Voltage Directive).

Schematic circuit distributor with shielded electric cable and shielded installation boxes

Schematic circuit distributor with shielded electric cable and shielded installation boxes

Checking the efficiency of the LF shielding

The screening is checked according to TCO’99, Volume I (MPR II) and DIN EN 50279 (measuring distance 30 cm, measurement against earth, free cable run over several metres, no connection areas, field-free laboratory conditions). The alternating electric field is measured in volts per meter, or V/m for short.

  • Unshielded installation cables: 30 – 80 V/m
  • Foil-shielded NYM-(St) or (N)HXMH(St) cable: below 1 V/m
  • Guideline value for building biology electrical installations: max. 10 V/m

Tips for comparing prices for shielded electrical cables

It is common in the cable industry for cables to be sold at a “cable price” with no copper content. Since the raw material prices are constantly changing, a “copper surcharge” is also levied, which is advertised as “plus a copper surcharge of € 150 per 100 kg of copper, the DEL notice is relevant on a daily basis”. The stated “daily price” of € 150.00 / 100 kg is from 2002, as of 2011 we are at around € 500.00 to 600.00 / 100 kg. This increases the actual cable price enormously compared to the list price! For this reason, all prices of our shielded cables INCLUDE copper surcharge!

Our electrical cable range at a glance

from:  137,00
This product has multiple variants. The options may be chosen on the product page
from:  97,00
This product has multiple variants. The options may be chosen on the product page
from:  105,00
This product has multiple variants. The options may be chosen on the product page
from:  78,00
This product has multiple variants. The options may be chosen on the product page
from:  5,60
This product has multiple variants. The options may be chosen on the product page
Weight N/A
Dimensions N/A
Variants

5x 2.5 mm²

Length  

25 meters, 100 meters

Field type

LF (low-frequency electric alternating field)

Country of origin

Germany

Colour white
Length 25 or 100 meters ring
Load Operating voltage max. 250VAC / 50Hz – 16A according to IEC 320-1; DIN VDE 0100
Cross-cuts / Ø: 5x 2.5 mm² – Ø 13 mm ± 0.2 mm – + Shielding wire 1.5 mm²
Twisting: SZ stranding – number of strokes 7 – reduction of the alternating magnetic field
Bending radius: according to DIN VDE 0298, not moved approx. 4 x diameter
Composition: Core insulation: halogen-free(cross-linked PE polyethylene 2XI1)according to DIN VDE 0276 part 604
Sheath: plastic inner sheath and outer sheath halogen-free PE-polymer mixture HM2 acc. to DIN VDE 0250 part 214 – polymers PE-EVA mixture granulate – flame retardant aluminium trihydroxide (ATH) powder no plasticisers
Wire cores: individually insulated – bare conductor, single wire
Shield: Plastic-coated aluminium strip, two-wire Cu 1.0 mm²
Protection class: 1 – according to DIN VDE 0295
Check: DIN VDE 0472, part 266-2- 4 test type C or IEC 332.3 TCO’99, volume I (MPR II) and DIN EN 50279 (measuring distance 30 cm, measurement against earth, free cable run over several metres, no connection areas, field-free laboratory conditions)
Scope of application: On, in and under plaster (DIN VDE 0298 Part 3).
Dry and damp rooms, wooden stud walls, hollow walls, concrete and masonry (except direct embedding in vibrated or tamped concrete)
Entire home
Computer rooms
Hospitals and public buildings

Reviews

There are no reviews yet

Add a review
(N)HXMH(St)-J 5x 2,5 mm² shielded installation cable | halogen-free | plasticizer-free | electric cable for shielding alternating electrical fields LF | 41-4360 (N)HXMH(St)-J 5x 2,5 mm² shielded installation cable | halogen-free | plasticizer-free | electric cable for shielding alternating electrical fields LF | 41-4360
Rating*
0/5
* Rating is required
Your review
* Review is required
Name
* Name is required
Add photos or video to your review

You may also like…

(15) from:  8,90
This product has multiple variants. The options may be chosen on the product page
Close Popup

We use cookies to give you the best online experience. By agreeing, you accept the use of cookies in accordance with our cookie policy. Further surfing in the web shop automatically leads to approval.

Close Popup
Privacy Settings saved!
Privacy Settings

When you visit any web site, it may store or retrieve information on your browser, mostly in the form of cookies. Control your personal Cookie Services here.

These cookies are necessary for the website to function and cannot be switched off in our systems.

Technical Cookies
In order to use this website we use the following technically required cookies
  • wordpress_test_cookie
  • wordpress_logged_in_
  • wordpress_sec
  • tk_lr
  • tk_or
  • tk_r3d

Onlineshop
To use this online shop, i.e. for shopping cart and order processing, we use the following technically necessary cookies and services:
  • woocommerce_cart_hash
  • woocommerce_items_in_cart

GDPR
To enable the GDPR service on this website, we use the following technically necessary cookies:
  • wordpress_gdpr_allowed_services
  • wordpress_gdpr_cookies_declined
  • wordpress_gdpr_first_time
  • wordpress_gdpr_first_time_url

Decline all Services
Save
Accept all Services