Visa
Revolut
Apple Pay
PayPal
Amazon
Klarna

Shielded (N)YM(St)-J electric cable. BIO electric cable to prevent electric fields.

 2,20

Cost-effective shielded cable to prevent LF electrosmog caused by low-frequency electric fields. These shielded sheathed cables are (N)YM(St)-J BIO cables. All prices include a copper surcharge.

Quantity = Number of running meters
Delivery time: around 3-7 business days | Purchase on account not possible

Volume discount from 50 meters (Price update in the cart)
up to 49 meters from 50 meters
depending on the variant 10% discount
Shielded BIO cable to protect against electric waves (LF)
Shielded BIO cable to protect against electric fields (LF)

Cheap, shielded sheathed cable to prevent LF electrosmog from power lines. Cost-effective (N)YM(St)-J BIO electric cables.

This very cost-effective shielded sheathed cable enables effective attenuation of low-frequency electric fields. Let’s consider that a standard electric cable, laid while building the room or house, produces a strong electric alternating field that can reach up to 2 meters in the room. And because the power line in the floor, ceiling, and walls are continuously under power of 16 amps and 220 volts, LF electrosmog is a theme 24/7 – 24 hours a day and 7 days a week.

With this shielded electric cable, also known as BIO cable, this problem is avoided from the outset. The low-frequency alternating fields automatically produced by the conventional household alternating current do not even leave the coated electric cable.

This (N)YM(St)-J shielded electric cable can be laid on and under plaster, in dry or humid rooms, on masonry, and on concrete. It is also suitable for outside use as long as it is protected from direct sunlight. It cannot be directly embedded into shaken, vibrated, or tamped concrete.

Important information about shielded home wiring:
In conjunction with shielded in-wall or flush-mounted boxes, this is the most effective way of shielding against electrosmog caused by electric fields. The commissioned electrician must be informed of the decision to use BIO cable BEFORE the tender. Laying this cable is a lot harder for the electrician, and the tender could be rejected as a result. Don’t be put off by this, just ask the next electrician. The extra effort to achieve an electrosmog-free result is always worth it.

Installing (N)YM(St)-J shielded electric cable

When installing, connect the ground wiring of the junction box to the ground wiring of the cable! Always connect yellow-green to yellow-green, do not connect them to the auxiliary wire in any case! Protect the auxiliary wire and toil with insulating tube, there can be no conductive parts in the junction box! The screen connection = lay the auxiliary wire to one side on the potential bonding bar. Do not use unshielded and shielded cables together.

Available variants of the (N)YM(St)-J shielded electric cable

Wire count / size Outer diameter Cable weight
3 x 1.5 mm² 10.5 mm 154 g/m
3 x 2.5 mm² 12.0 mm 217 g/m
5 x 1.5 mm² 12.0 mm 208 g/m
5 x 2.5 mm² 13.5 mm  280 g/m

Construction of the (N)YM(St)-J shielded electric or BIO cable

Construction of the (N)YM(St)-J shielded BIO cable
Construction of the (N)YM(St)-J shielded BIO cable

1) Single-wire copper conductor
2) Insulation: Cross-linked polyethylene
3) Joint PVC core covering
4) (St) screen: Coated aluminum foil with 1.5 mm² ground wire
5) PVC outer sheath

Technical information on the (N)YM(St)-J shielded electric cable

  • Shielded PVC sheathed cable (following DIN VDE 0250 Part 204/209)
  • Self-extinguishing and flame-retardant PVC according to DIN VDE 0482 Teil 265-2-1 / EN 50265-2-1 /IEC 60332-1 (in compliance with DIN VDE 0472 Part 804 Inspection type B)
  • CE = conforms to the EG low voltage guidelines 73/23/EWG or 93/68/EWG
  • DC resistance following DIN VDE 0295
  • Operating temperature: -40°C to +70°C. Installation temperature: -5°C to +70°C
  • Nomninal voltage U0/U: 300/500 V, current load according to VDE 0100
  • Test procedures according to DIN VDE 0472, test AC voltage 50 Hz, 3500 V<
  • Bending radius according to DIN VDE 0298: 4 x D
  • Radiation resistance: Up to 80×106 cJ/kg (up to 80 Mrad)
  • Quantity: In rolls of 1.0 running meter. If tailor-cut for a customer, it cannot be revoked or cancelled. Request a free test sample before ordering.
  • Application: Reduce LF fields
  • Field type: LF (low-frequency alternating fields)

Tips to compare shielded electric cable prices

In the cable industry, it is normal to sell cable for a “cable price” without including the copper. Because the price of raw materials constantly changes, a “copper surcharge” was levied and the cables are advertised with “Plus a copper surcharge of €150 per 100 kg, the notice is up to date”. The indicated “market price” of €150.00/100 kg is from 2002, in 2011, it is more in the range of around €500 to €600/100 kg. As a result, the actual cable price is a lot higher than the listed price! For this reason, all of the prices of our shielded cable INCLUDES copper surcharge!

No cancellation for the shielded electric cables

Like for cuts, there is no right to return shielded electric cables.

Please note that cancellations do not apply to these products, because they were cut to the customer’s specifications. Reselling a tailored item is no longer possible.

Documentation for biological electrical installations in construction

Technical data Connecting and grounding shielded cables and sockets
Weight N/A
Dimensions N/A
Variants

, , ,

Length

Running meter

Field type

LF (low-frequency electric alternating field)

GTIN

4260103668217,4260103668224,4260103668231,4260103668248

Brand

Country of origin

Germany

Reviews

There are no reviews yet

Add a review
Shielded (N)YM(St)-J electric cable. BIO electric cable to prevent electric fields. Shielded (N)YM(St)-J electric cable. BIO electric cable to prevent electric fields.
Rating*
0/5
* Rating is required
Your review
* Review is required
Name
* Name is required
Add photos or video to your review

You may also like…

Close Popup

We use cookies to give you the best online experience. By agreeing, you accept the use of cookies in accordance with our cookie policy. Further surfing in the web shop automatically leads to approval.

Close Popup
Privacy Settings saved!
Privacy Settings

When you visit any web site, it may store or retrieve information on your browser, mostly in the form of cookies. Control your personal Cookie Services here.

These cookies are necessary for the website to function and cannot be switched off in our systems.

Technical Cookies
In order to use this website we use the following technically required cookies
  • wordpress_test_cookie
  • wordpress_logged_in_
  • wordpress_sec
  • tk_lr
  • tk_or
  • tk_r3d

Onlineshop
To use this online shop, i.e. for shopping cart and order processing, we use the following technically necessary cookies and services:
  • woocommerce_cart_hash
  • woocommerce_items_in_cart

GDPR
To enable the GDPR service on this website, we use the following technically necessary cookies:
  • wordpress_gdpr_allowed_services
  • wordpress_gdpr_cookies_declined
  • wordpress_gdpr_first_time
  • wordpress_gdpr_first_time_url

Decline all Services
Save
Accept all Services